船舶滞留缺陷学习(九)

2023-08-09

79. Fire alarm station not working properly (Lines 1, 2, 3, 4, 6, 10, 11, 12, 13), fire alarm.(ISM) 火灾报警系统1, 2, 3, 4, 6, 10, 11, 12, 13路不工作。

80. The fire detection and alarm system at the bridge and fire control station does not work compromising the fire safety of all accommodatton spaces and engine room(控制站和驾驶台的火灾报警系统不工作,危及舱室和机舱安全)

81. The fire detector in boiler area found blocked & obstructed with plastic cover. It's fire detector for in case of fire is not ready for use(锅炉附近火灾探测报警探头被塑料包裹,不能立即可用)

82. Fire alarm panel found in "general fault" condition due to some smoke detectors inoperative(火灾报警通用面板由于烟雾探头故障导致故障报警。)

83. Fire alarm panel on bridge two zone disablements.(驾驶台火灾报警面板有两个区域故障)

84. Fire detection panel - found switched off during inspection. After switching on, SW POS WARNING signal appears. During test, some alarm appeared on panel.(PSC检查期间,火灾报警系统被关闭,打开后出现报警,测试时,无报警出现)

   关于火灾报警的检查套路:

第一招:人为拆除一个火警探头,观察该系统是否发出正确位置的故障报警显示,复位后,查看报警是否消除。

第二招:选一个火警探头,采取模拟火灾烟雾,确认是否能够及时发出正确位置的声光信号,并等待两分钟能否发出全船报警信号。

第三招:断开系统主电源,查看控制板是否发出声、光故障信号,这一信号应与失火信号有区别。

第四招:测试手动报警按钮,是否发出正确的声光报警信号。